ISSUE:
The Assembly drawing of A604 was in the file path folder Details of the reflective project. However, it is not visible in the Document manager of the structure.

How to retrieve missing drawings from the DOCUMENT MANAGER pic1

RESOLUTION:
Delete the.UPD file of A604 assembly drawing from the server location. Now that the link is broken you will have to cancel the document from the drawing and register it back.

How to retrieve missing drawings from the DOCUMENT MANAGER pic2

I went back to the model structure and “Cancelled document from drawing” then used Register documents to model.

How to retrieve missing drawings from the DOCUMENT MANAGER pic3

If drawing still does not show in the Document Manager.

How to retrieve missing drawings from the DOCUMENT MANAGER pic4

Use the Model Browser to locate the element and isolate the element.

How to retrieve missing drawings from the DOCUMENT MANAGER pic5

Use the same drawing process used to create the former drawings. 

For this example, a drawing process of “Selected Assemblies each on an ANSI-B process was used. The drawing number was changed to 604.

How to retrieve missing drawings from the DOCUMENT MANAGER pic6

The drawing is now listed in the document manager and ready for viewing.

 How to retrieve missing drawings from the DOCUMENT MANAGER pic10

Watch the video to see how it’s done!

For additional information, Graitec customers may contact their local support teams.

Useful links for Advance Steel user

Wondering if Advance Steel can do "this" or "that", or if there is a better way to do something?

We have various ways to assist with your questions.

Image size exceeds the storage capacity warning in...
Creating a User Pan tread for the stair macro in A...

Related Posts

Comment for this post has been locked by admin.
 

By accepting you will be accessing a service provided by a third-party external to https://www.graitec.ca/

Autodesk gold partner 250